EEVblog #699 - Rigol DS1054Z Oscilloscope Jitter Fix Testing

  • 9 years ago
Dave tries out the new DS1054Z firmware from Rigol that is supposed to fix the 5us delay jitter issue, and the AC Trigger Coupling jitter issues.
Have they fixed it, or is there still a problem?
What caused the 5us jitter issues to begin with, Dave also investigates the ADC PLL based sample clock with an e-Field probe and the Rigol DSA815 spectrum analyser.
Did Rigol also change the PLL coefficients?
Previous video: https://www.youtube.com/watch?v=kcOdzFaIYNE

Review Summary: http://youtu.be/ETCOhzU1O5A
Full features review: http://youtu.be/W2qdtQkBKhc
Teardown: http://youtu.be/kb9P1Am9aFU
Jitter Problem: http://youtu.be/kcOdzFaIYNE
Reverse Engineering: http://youtu.be/lJVrTV_BeGg

ADF4360 PLL datasheet: http://www.analog.com/static/imported-files/data_sheets/ADF4360-7.pdf

Forum: http://www.eevblog.com/forum/blog/eevblog-699-rigol-ds1054z-oscilloscope-jitter-fix-testing/

EEVblog Main Web Site: http://www.eevblog.com
The 2nd EEVblog Channel: http://www.youtube.com/EEVblog2

Support the EEVblog through Patreon!
http://www.patreon.com/eevblog

EEVblog Amazon Store (Dave gets a cut):
http://astore.amazon.com/eevblogstore-20
Donations:
http://www.eevblog.com/donations/
Projects:
http://www.eevblog.com/projects/
Electronics Info Wiki:
http://www.eevblog.com/wiki/